TM 9--2350--292--20--2
0604 00--4
AUXILIARY POWER UNIT CRANKCASE OIL DRAIN LINES REPAIR --
CONTINUED
0604 00
Installation
1. Apply sealing compound to all pipe threads prior to installation.
2. Install pipe nipple (26) in APU assembly.
3. Install pipe tee (15) on pipe nipple (26).
4. Install pipe bushing (25) in pipe tee (15).
5. Install drain valve (21) in outlet end of pipe bushing (25).
6. Install screw (22) and handle (23) on drain valve (21).
7. Install tube (24) in outlet end of drain valve (21).
8. Install lock--release lever (20) and oil drain instruction plate (19) to drain valve (21) with two screws (16), two new
lockwashers (17) and two nuts (18).
9. Attach pipe elbow (13) to end of pipe nipple (14).
10. Install other end of pipe nipple (14) to inlet end of pipe tee (15).
Figure 334
13
14
24
21
20
23
19
16
25
15
22
26
18
17