APPENDIX I: DEEP WATER FORDING KIT
TM 9-2350-256-20
I-13 FIRE EXTINGUISHER NOZZLES AND ELECTRICAL CONNECTIONS IN
ENGINE COMPARTMENT
1
Open battery access doors.
2
Clean and dry all electrical connections to which sealer is to be applied.
WARNING
Do not seal battery cap vents.
3
Apply asbestos sealing compound (Table I-1, item 5) to all 15 battery terminals and ground (1).
4
Close battery access doors.
5
Apply adhesive sealant (Table I-1, item 4) to main engine ground (2) and slave ground (3).
CAUTION
Do not apply adhesive sealant to fire extinguisher nozzle caps.
6
Install kit-furnished rubber caps (4) in five fire extinguisher nozzles (5).
1-14 CAULKING EXTERIOR FIRE EXTINGUISHER REMOTE CONTROL
WARNING
Dry-cleaning solvent used to clean parts is potentially dangerous to personnel and
property. Do not use near open flame or excessive heat. Flash point of solvent is 138
degrees () Fahrenheit (59 Celsius).
I-12