SECTION II: INSTALLATION PROCEDURESTM 9-2350-256-201Clean area around exterior and interior with dry-cleaning solvent.2Apply caulking compound (Table I-1, item 3) allaround areas indicated (1).I-15 OTHER APPLICATIONS OF CAULKING COMPOUND1Pull main winch cable (1) in until a light pressureis applied between clevis and opening. Sealexposed area around cable with caulkingcompound (Table I-1, item 3).2Seal hull front cover (2) with caulking compound(Table I-1, item 3).3Seal all around cover plate (3) at opening in hullfront cover (2) with caulking compound (Table I-1, item 3).4Seal at both ends of cover plate (4) with caulkingcompound (Table I-1, item 3).5Seal personnel doors with caulking compound(Table I-1, item 3) only if watertight seal cannotbe obtained with regular door seals.6Check drain plugs in exterior stowagecompartments to ensure watertight fit. Sealstowage compartment doors (5 and 6) withcaulking compound (Table I-1, item 3).7Use caulking compound (Table I-1, item 3) toseal around all mounting surfaces of deep waterfording components, such as right and left engineair intake pipes, personnel heater air intake coverand exhaust, acetylene vent, fuel tank vent, andengine generator vent.I-13