SECTION II: INSTALLATION PROCEDURES TM 9-2350-256-207Connect bent tube (15) to hose (13) with clamp(16).8Connect one end of hose (17) to bent tube (15)with clamp (18) and other end to bent tube (19)with clamp (20).9Secure hose (17) to existing fire extinguishertubing (21) with clamp (22).10Install grommet (23) in opening from which rearintermediate right access cover (3) was removed.11Route hose (24) through grommet (23) andattach one end to bent tube (19) with clamp (25).12Remove cover (26) from hull by removing twoexisting screws (27) and two lockwashers (28).Retain screws.13Install adapter (29) and gasket (30) to outside ofhull with two screws (27) and two newlockwashers (28).14Connect second end of hose (24) to adapter (29)and secure with clamp (31).15Secure hose (24) to bulkhead with clip (32), newlockwasher (33), and screw (34).16Connect adapter (35) to adapter (29) usingspanner wrench (Table I-1, item 10).17Attach seal (36) to adapter (35) with clamp (37).18Wrap asbestos tape several times aroundpersonnel heater exhaust (38), applying sodiumsilicate (Table I-1, item 6) while wrapping.I-11