APPENDIX I: DEEP WATER FORDING KIT
TM 9-2350-256-20
1-11 CREW FAN AND BOOM BOOT DRAIN SHUTOFF CLAMP
1
Tape crew fan switch, located on accessories
panel, to OFF position with adhesive tape (Table
I-1, item 7).
2
Remove ventilating blower assembly (1) by
removing three screws (2), three lockwashers (3),
and three nuts (4).
3
Apply caulking compound (Table I-1, item 3) to
seal assembly (5) and place seal assembly into
opening of crew fan housing (6). Tighten seal
assembly screws until watertight fit is obtained.
4
Install ventilating blower assembly (1) with three
screws (2), three new lockwashers (3), and three
nuts (4).
5
Install kit-furnished clamp (7) on crew fan
housing (6) drain hose.
6
Install one kit-furnished clamp (8) on right and
left drain hoses of boom cylinder boot (9).
1-12 BILGE PUMP
1
Remove rear center floor plate (1) and stowage
basket forward intermediate left floor plate (2),
and retain.
2
Remove rear intermediate right access cover (3).
CAUTION
Do not apply adhesive sealant to fire
extinguisher nozzle caps.
3
Install kit-furnished rubber cap (4) in two fire
extinguisher nozzles (5) in main winch
compartment.
NOTE
All of the following items are kit furnished unless otherwise noted.
4
Install strainer assembly (6) and bilge pump assembly (7) with four screws (8), four new lockwashers (9),
and eight flat washers (10).
5
Install bent tube (11) with spanner wrench (Table I-1, item 10) and existing wiring harness (12) to bilge
pump assembly (7).
6
Connect hose (13) to bent tube (11) with clamp (14).
I-10