TM 9--2350--292--20--10095 00--4MAIN WINCH LEVEL WINDER FAILS TO OPERATE -- CONTINUED0095 00HIs pressure at port EXT within 60 psi of pressure atsupply port P and is pressure at port RET 60 psi orless when level winder cylinder is retracting and ispressure at port RET within 60 psi of pressure atsupply port P and is pressure at port EXT 60 psi orless when level winder cylinder is extending?CONTINUED FROM STEP GnoyesCONTINUED ON NEXT PAGE1. Remove gauge from V1 port, reattach hoseand install gauge with 1/4--inch tee betweenEXT port of level winder cylinder and attachinghose.2. Remove gauge from V2 port, reattach hoseand install gauge with 1/4--inch tee betweenRET port of level winder cylinder and attachinghose.3. Perform steps 4 thru 8 of Step F.Go to Step J.IAre plates properly aligned and free of restrictions andbinding?Inspect the level winder subplate assembly ballisticplates for alignment, binding and restrictions.noyesNotify Direct SupportMaintenance.Remove restrictionsand free bound parts.Verify fault is corrected.If parts are damagedand must be replacednotify Direct SupportMaintenance.WARNING