MAIN WINCH LEVEL WINDER FAILS TO OPERATE -- CONTINUED
0095 00
H
Is pressure at port EXT within 60 psi of pressure at
supply port P and is pressure at port RET 60 psi or
less when level winder cylinder is retracting and is
pressure at port RET within 60 psi of pressure at
supply port P and is pressure at port EXT 60 psi or
less when level winder cylinder is extending?
CONTINUED FROM STEP G
no
yes
CONTINUED ON NEXT PAGE
1. Remove gauge from V1 port, reattach hose
and install gauge with 1/4--inch tee between
EXT port of level winder cylinder and attaching
hose.
2. Remove gauge from V2 port, reattach hose
and install gauge with 1/4--inch tee between
RET port of level winder cylinder and attaching
hose.
3. Perform steps 4 thru 8 of Step F.
Go to Step J.
I
Are plates properly aligned and free of restrictions and
binding?
Inspect the level winder subplate assembly ballistic
plates for alignment, binding and restrictions.
no
yes
Notify Direct Support
Maintenance.
Remove restrictions
and free bound parts.
Verify fault is corrected.
If parts are damaged
and must be replaced
notify Direct Support
Maintenance.