TM 9--2350--292--20--1
0095 00--8
MAIN WINCH LEVEL WINDER FAILS TO OPERATE -- CONTINUED
0095 00
O
Is dual check valve free of restrictions?
CONTINUED FROM STEP M
no
yes
Inspect level winder dual check valve for
restrictions.
Remove restrictions.
Verify fault is corrected.
P
Does roller bracket assembly, diamond screw, and tube
nut follower operate properly?
1. Inspect the roller bracket assembly, diamond
screw and tube nut follower for proper
operation.
2. Shut down
hydraulics
and engine
(TM 9--2350--292--10).
no
yes
Repair or replace
bracket assembly
(WP 0508 00). Verify
fault is corrected. If
diamond screw is
faulty, notify Direct
Support Maintenance.
Replace shoulder bolt
(WP 0508 00). Verify
fault is corrected.
Notify Direct Support
Maintenance.
CONTINUED FROM STEP L
END OF TASK