TM 9--2350--292--20--20634 00--6AUXILIARY POWER UNIT GENERATOR REPLACEMENT -- CONTINUED0634 00Installation--Continued9. Install two wires (3 and 4), three new lockwashers (2) and nut (1, supplied with generator) on terminal E of gener-ator (5).10. After generator leads are installed, apply adhesive to all exposed electrical terminals.11. Connect APU ground hop kit (WP 0588 00) and start APU (TM 9--2350--292--10). After APU is started check APUgenerator gauge to make sure generator is operating properly.Figure 343324521NOTEFOLLOW--ON MAINTENANCE:Install APU hydraulic pump (WP 0547 00)Install APU engine support (WP 0590 00)END OF TASK