TM 9--2350--292--20--20665 00--2AUXILIARY POWER UNIT SHUT--DOWN SOLENOID, BRACKET AND FUELSTOP ABSORBER REPLACEMENT (HATZ) -- CONTINUED0665 00Removal--Continued6. Remove screw (17) and fuel stop absorber (8) from dampener bracket (18).7. Remove nut (19), lockwasher (20) and dampener bracket (18). Discard lockwasher.NOTERemove the attaching hardware in step 8 only if parts aredamaged.8. Remove two nuts (21), lockwasher (22), two flat washers (23) and screw (24) from APU. Discard lockwasher.9. Inspect parts for damage and replace as required.Installation1. Install screw (24), two flat washers (23), new lockwasher (22) and two nuts (21), if removed.2. Install dampener bracket (18) with nut (19) and new lockwasher (20).3. Install fuel stop absorber (8) with screw (17).17824232219201821
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business