SECTION V: TROUBLESHOOTING TM 9-2350-256-20WARNINGRemove all jewelry such as rings, dog tags,bracelets, etc. If jewelry contacts a metalsurface a direct short may result in instantheating of tools, damage to equipment, andinjury or death to personnel.DPlace red lead of multimeter in socket A of wire 38/59and black lead to ground. Turn MASTER switch onand check for voltage. Turn MASTER switch OFF. Ifvoltage is present, go to step E. If voltage is notpresent, go to step G.EReconnect electrical accessories panel wiring harnessto electrical accessories panel. Remove four screws(1) and four lockwashers (2) and release electricalaccessories panel (3). Disconnect wire 38/518 fromwinch light switch side of 15 A circuit breaker. Placered lead of multimeter on terminal of 15 A circuitbreaker and black lead to ground. Turn MASTERswitch on and check for voltage. Turn MASTERswitch OFF. If voltage is present, repair/replace wire38/518 of bilge pump main power wiring harness from15 A circuit breaker to electrical accessories panelwiring harness (see paragraph 6-84). If voltage is notpresent, go to step F.2-259