TM 9--2350--292--20--20667 00--14DEEP WATER FORDING KIT -- CONTINUED0667 00Installation--ContinuedVENTILATION BLOWER SEAL AND BOOM FOOT DRAIN SHUTOFF CLAMPS1. Tape VENT BLOWER switch (1) on the Accessories Panel (2) in the OFF position.NOTENote the quantity and position of shim(s) being removedto ensure shim(s) are installed in the same position.2. Remove three screws (3), three nuts (4), three flat washers (5), three lockwashers (6), ventilation blower assem-bly (7) and shims (8) from elbow mount (9) and inlet port (10). Retain screws, nuts, flat washers, ventilation blow-er assembly and shims. Discard lockwashers.3. Apply caulking compound (11672186) to seal (11). Install seal (11) in inlet port (10). Tighten four screws in seal(11) until a watertight fit is obtained.4. Position shims (8) and ventilation blower assembly (7) on elbow mount (9) and at inlet port (10), secure with threescrews (3), three new lockwashers (6), three flat washers (5) and three nuts (4).5. Install one shutoff clamp (12) each on ventilation blower drain hose (13) and right and left boom cylinder bootdrain hoses (14). Tighten shutoff clamps (12) to close drain hoses (13 and 14).Figure 36Figure 360345678910111412131212