TM 9--2350--292--20--20667 00--10DEEP WATER FORDING KIT -- CONTINUED0667 00Installation--ContinuedMain Engine Exhaust Outlet Pipes (Continued)5. Install two clamps (11) around each flexible exhaust pipe (9), secure to top rear engine deck (4) with eight screws(1) and eight new lockwashers (2).6. Install two exhaust elbows (6) on two flexible exhaust pipes (9). Apply bead of adhesive sealant (12477551) tojoint to prevent entry of water. Secure two flexible exhaust pipes (9) and two elbows (6) with two clamps (5).7. Start and operate main engine (TM 9--2350--292--10).WARNING8. While the exhaust system is hot, tighten all exhaust joint clamps.Figure 3611245692111114