TM 9--2350--292--20--2
0667 00--10
DEEP WATER FORDING KIT -- CONTINUED
0667 00
Installation--Continued
Main Engine Exhaust Outlet Pipes (Continued)
5. Install two clamps (11) around each flexible exhaust pipe (9), secure to top rear engine deck (4) with eight screws
(1) and eight new lockwashers (2).
6. Install two exhaust elbows (6) on two flexible exhaust pipes (9). Apply bead of adhesive sealant (12477551) to
joint to prevent entry of water. Secure two flexible exhaust pipes (9) and two elbows (6) with two clamps (5).
7. Start and operate main engine (TM 9--2350--292--10).
WARNING
8. While the exhaust system is hot, tighten all exhaust joint clamps.
Figure 361
1
2
4
5
6
9
2
1
11
11
4