TM 9--2350--292--20--2
0667 00--7
DEEP WATER FORDING KIT -- CONTINUED
0667 00
Installation--Continued
APU AND PERSONNEL HEATER EXHAUST SEALS
1. Attach two S--hooks (1) on each end of chain (2). Install one S--hook (1) attached to end of chain (2) to grating on
muffler cover (3).
2. Attach other S--hook (1) on end of chain (2) to seal (4); install seal (4) in APU muffler exhaust outlet tube (5). If
necessary, seal (4) can be adjusted by rotating lever (clockwise to increase compression and counter--clockwise
to decrease tension). Bend locking tab on seal (4) to adjust for fit on exhaust outlet tube (5).
3. Attach two S--hooks (1) on each end of chain (6). Install one S--hook (1) attached to end of chain (6) to grating on
muffler cover (3).
4. Attach other S--hook (1) on end of chain (6) to seal (7); install seal (7) in personnel heater exhaust outlet tube (8).
If necessary, seal (7) can be adjusted by rotating lever (clockwise to increase compression and counter--clockwise
to decrease tension).
Figure 359
1
1
1
1
2
4
5
3
6
8
7