TM 9--2350--292--20--20667 00--7DEEP WATER FORDING KIT -- CONTINUED0667 00Installation--ContinuedAPU AND PERSONNEL HEATER EXHAUST SEALS1. Attach two S--hooks (1) on each end of chain (2). Install one S--hook (1) attached to end of chain (2) to grating onmuffler cover (3).2. Attach other S--hook (1) on end of chain (2) to seal (4); install seal (4) in APU muffler exhaust outlet tube (5). Ifnecessary, seal (4) can be adjusted by rotating lever (clockwise to increase compression and counter--clockwiseto decrease tension). Bend locking tab on seal (4) to adjust for fit on exhaust outlet tube (5).3. Attach two S--hooks (1) on each end of chain (6). Install one S--hook (1) attached to end of chain (6) to grating onmuffler cover (3).4. Attach other S--hook (1) on end of chain (6) to seal (7); install seal (7) in personnel heater exhaust outlet tube (8).If necessary, seal (7) can be adjusted by rotating lever (clockwise to increase compression and counter--clockwiseto decrease tension).Figure 35911112453687