TM 9--2350--292--20--2
0499 00--6
MAIN WINCH WIRE ROPE ASSEMBLY REPLACEMENT -- CONTINUED
0499 00
Installation -- Continued
8. Repeat steps 6 and 7 as necessary until 1/8 -- 1/4 inch (3.2 -- 6.4 mm) of wedge (6) and approximately 1.0 inch (25.4
mm) of wire rope (7) is left exposed.
9. Secure and tighten wedge (6) to drum (1) with two wedge clamping screws (2). Torque screws to 270 -- 300 lb--ft
( 366.1 -- 406.8 NSm).
10. Install new nonelectrical wire (5) through two wedge clamping screws (2).
Figure 261
1
7
1
2
7
6
1.0
(25.4 mm)
5